We sell the best and fix the rest!

56 Calle Gazapo
Rancho Santa Margarita, CA • 92688

Call us for a free estimate or in-home
demonstration - 949-228-7364
An example of what our customers are saying:     
 

  VACUFLO TRUE CYCLONIC®

PERFORMANCE

260

The perfect choice for homes up to 3,000 square feet

466Q

The perfect choice for homes up to 5,000
square feet

566Q

The perfect choice for homes up to 8,000
square feet

760

The perfect choice for homes up to 12,000 square feet

960

The perfect choice for homes up to 18,000 square feet

MaxAir®

The perfect choice for homes up to 22,000 square feet


Sealed Vacuum (H20 lift)

112"

121"

135"

112"

125"

208"

CFM Max

116

114

118

232

232

122

Max Air Watts*

443

477

535

886

990

903

Volts

120

120

120

120

120

240

Max/Avg Amps**

14.2/10.5

14.9/11.6

15.6/12.0

28.4/21.0

29.0/21.0

13.8/13.0

Level of Quietness dB***

70.1 dBA

59.7 dBA

60.7 dBA

67.8 dBA

70.9 dBA

n/a

FEATURES


Filtration

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

True Cyclonic, requires no bags or filters

n/a

Collection Capacity

5.5 gallons

6 gallons

6 gallons

6 gallons

13.5 gallons

6 gallons

Low Voltage Controls

24 V PC Board

24 V PC Board

24 V PC Board

24 V PC Board (2 single pole relays)

24 V PC Board (2 single pole relays)

n/a

Overload Heat Protection

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

2 pushbutton resettable circuit protector

2 p ushbutton resettable circuit protector

n/a

Warranty

Lifetime Limited +3

Lifetime Limited +3

Lifetime Limited +3

Lifetime Limited +3

Lifetime Limited +3

n/a

Construction

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

18 gauge steel Powder-coated finish

n/a

Dimensions/Weight

12 5/8" dia. x 36 3/8" high / 26 pounds

12 5/8" dia. x 38 7/8" high / 28 pounds

12 5/8" dia. x 40 1/4" high / 31 pounds

12 5/8" dia. x 42 1/8" high / 43 pounds

18 1/4" dia. x 40 1/2" high / 84 pounds

n/a

INSTALLATION


Electrical Requirements

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  30 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type L5-30
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  30 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type L5-30
  receptacle with
  grounding wire

n/a

Mounting Requirements

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

n/a

Exterior Venting

Single exhaust muffler included

Single exhaust muffler included

Single exhaust muffler included

Separate dual exhaust 2 mufflers included

Separate dual exhaust 2 mufflers included

n/a




back to top


* ASTM recognizes air watts as air power and is defined as "above the floor cleaning potential."

** Maximum amps refer to the potential amount of current if the power unit is running in a stand-alone situation. (no tubing or accessories attached). Average amps refer to the actual amount of current used when the power unit is in typical operation (installed, with accessories attached).

*** ASTM draft F11.50.07 test method was used to determine dBA ratings. Sound levels were measured at 6' from the power unit. All power units were exhausted outdoors.

© 2016 Doran, Inc. All rights reserved. All brands and trademarks are property of their respective owners.