We sell the best and fix the rest!

56 Calle Gazapo
Rancho Santa Margarita, CA • 92688

Call us for a free estimate or in-home
demonstration - 949-228-7364
An example of what our customers are saying:     
 

  VACUFLO FILTERED CYCLONIC™

PERFORMANCE

FC300

The perfect choice for homes up to 3,000 square feet

FC550

The perfect choice for homes up to 5,000
square feet

FC650

The perfect choice for homes up to 8,000
square feet

FC1550

The perfect choice for homes up to 18,000 square feet


Sealed Vacuum (H20 lift)

106"

125"

141"

128"

CFM Max

115

121

124

228

Max Air Watts*

422

520

575

1010

Volts

120

120

120

240

Max/Avg Amps**

11.2/9.9

14.0/11.3

15.7/12.4

13.4/11.6

Level of Quietness dB***

73.7 dBA

64.2 dBA

62.8 dBA

66.0 dBA

FEATURES


Filtration

Filtered Cyclonic 7" replaceable filter cartridge

Filtered Cyclonic 7" replaceable filter cartridge

Filtered Cyclonic 7" replaceable filter cartridge

Filtered Cyclonic 10" replaceable filter cartridge

Collection Capacity

4 gallons

6 gallons

6 gallons

6 gallons

Low Voltage Controls

24 V PC Board

24 V PC Board

24 V PC Board

24 V PC Board (2 single pole relays)

Overload Heat Protection

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

2 pushbutton resettable circuit protector

Warranty

Lifetime Limited +1

Lifetime Limited +1

Lifetime Limited +1

Lifetime Limited +1

Construction

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

Dimensions/Weight

13" dia. x 31 3/8" high / 23 pounds

13" dia. x 39 5/8" high / 32 pounds

13" dia. x 39 5/8" high / 32 pounds

13" dia. x 44" high / 43 pounds

INSTALLATION


Electrical Requirements

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 240V, 50/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 6-15R
  receptacle with
  grounding wire

Mounting Requirements

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall.

Exterior Venting

None available

Optional exterior venting

Optional exterior venting

Optional exterior venting




back to top


* ASTM recognizes air watts as air power and is defined as "above the floor cleaning potential."

** Maximum amps refer to the potential amount of current if the power unit is running in a stand-alone situation. (no tubing or accessories attached). Average amps refer to the actual amount of current used when the power unit is in typical operation (installed, with accessories attached).

*** ASTM draft F11.50.07 test method was used to determine dBA ratings. Sound levels were measured at 6' from the power unit. All power units were exhausted outdoors.

© 2016 Doran, Inc. All rights reserved. All brands and trademarks are property of their respective owners.